Forklift Guides

Lithium-ion vs lead-acid forklift batteries

How lithium-ion and lead-acid forklift batteries compare on cycle life, charging, maintenance, cold storage, cost and safety, with figures from manufacturers and OSHA's charging rules.

Quick answerLead-acid batteries cost less up front but need regular watering, a full charge of about 8 hours plus cool-down, and spare batteries for multi-shift work. Manufacturers quote about 1,000 to 1,500 charge cycles. Lithium-ion batteries cost more but charge in 1 to 2 hours, can be opportunity charged on breaks, need no watering or gassing ventilation, and are quoted at several thousand cycles. The right choice depends on how many shifts you run and your total cost over the battery's life.
Lead-acid cycles
About 1,000 to 1,500 (Crown, Toyota)
Lithium-ion cycles
Up to 3,600 to 5,000+ quoted (Crown, Toyota)
Lead-acid full charge
About 8 hours, plus cool-down
Lithium-ion charge
About 1 to 2 hours from 20% (Toyota)

Electric forklifts now handle much of the indoor work in warehouses, and the battery is one of the biggest decisions when you buy or lease one. Lead-acid has been the standard for decades. Lithium-ion has become a mainstream alternative from every major manufacturer. This guide compares the two using figures published by battery and truck makers, which we've cross-checked against each other.

A note on the figures: most published comparisons come from manufacturers, who sell lithium-ion products, and their figures differ. Where they disagree we give the range and name the source. Treat cycle counts as indications, not guarantees, and compare the warranty terms of the specific battery you are offered.

The comparison at a glance

Lead-acidLithium-ion
Cycle lifeAbout 1,000 to 1,500 cycles (Crown); about 1,500 (Toyota)Up to 3,600 (Crown, cold storage article), up to 5,000 (Toyota); Crown also cites up to 9,000
Full charge timeAbout 8 to 10 hours, excluding cool-down (Crown)1 to 2 hours from 20% (Toyota); about 1 hour per 8 hours of use (Crown)
Cool-down after chargingYesNo (Crown)
Opportunity chargingGenerally not, unless designed for itYes, without affecting battery life (Crown, Toyota)
Watering and equalizingRequiredNone; sealed units
Gassing during chargingYes; needs ventilationNo gas emitted (Crown)
Power over the shiftFalls as the charge runs down (Hyster)Full power until nearly depleted (Hyster)
Cold storageCan lose 30% of rated capacity below 32°F (Crown)Works in chilled areas; heated options available
Upfront costLowerHigher
RecyclingNearly 100% recyclable (Crown)Developing, more complex (Crown)

Charging and shift patterns

This is where the two differ most. A conventional lead-acid battery is run down over a shift, then needs a long charge and time to cool. Crown puts the recharge at typically 8 to 10 hours, not counting cool-down. Bobcat describes the classic flooded battery routine as 8 hours of work, 8 hours of charging and 8 hours of cooling, and advises recharging when about 20 percent of charge remains. So in two- or three-shift operations, each truck usually needs spare batteries, swapped in a battery room with lifting equipment.

Lithium-ion batteries can be charged in short bursts during breaks. Toyota says its lithium-ion batteries charge from 20 percent to full in 1 to 2 hours, and that partial charging carries no lifespan penalty. Crown says there is no need to keep extra batteries for multi-shift operations, because the battery stays in the truck.

Maintenance

Flooded lead-acid batteries need regular care:

  • Watering: topping up cells with distilled or deionized water. Toyota and Bobcat both say to water after a full charge, not before.
  • Equalizing: a controlled overcharge on a schedule to balance the cells. Hyster lists equalizing, watering and off-gassing as lead-acid requirements.
  • Cleaning: keeping the battery top and terminals clean and free of corrosion.
  • Temperature: Toyota warns that heat from poor charging practice can take years off a battery's life.

Lithium-ion batteries are sealed. Crown says they don't need watering, and Toyota says no topping up or battery maintenance is required. They do rely on a battery management system (BMS), which Hyster says monitors cell voltage, temperature and overall battery health.

Safety and the charging area

OSHA's standard sets rules for lead-acid charging in paragraph 1910.178(g):

  • Charging must happen in areas designated for that purpose.
  • There must be facilities for flushing and neutralizing spilled electrolyte, fire protection, protection of chargers from damage by trucks, and ventilation to disperse fumes from gassing batteries.
  • A conveyor, overhead hoist or equivalent must be provided for handling batteries.
  • When mixing electrolyte, acid is poured into water, never water into acid.
  • Smoking is prohibited in the charging area, and open flames, sparks and electric arcs must be prevented.
  • Tools and metal objects must be kept away from the tops of uncovered batteries.

Lead-acid batteries are also very heavy. Bobcat notes they range from around 100 to 200 lb for small batteries to about 3,000 lb for large ones, which is why OSHA requires proper lifting equipment and why the battery forms part of the truck's counterweight. Battery acid can burn eyes and skin, so eye protection, gloves and eyewash facilities are standard in battery rooms.

Manufacturers say lithium-ion batteries don't emit gas during charging and so don't need special ventilated rooms. Toyota's BMS switches the power off if cells are damaged or at risk of overheating. Follow the battery maker's instructions for chargers, storage and damaged batteries.

Weight and counterweight

On an electric counterbalanced forklift the battery's weight is part of what keeps the truck stable. The data plate on an electric truck usually gives a minimum and maximum battery weight. Toyota says lithium-ion batteries are smaller and lighter than lead-acid, and Crown says they may need to be supplemented with additional counterweight to maintain performance specifications. Never fit a replacement battery that falls outside the plate's range without the manufacturer's approval; OSHA requires the manufacturer's written approval for modifications that affect capacity and safe operation (1910.178(a)(4)).

Cost

Lead-acid has the lower purchase price. Raymond put the cost of an industrial lead-acid lift truck battery at about $10,000 in 2015. Lithium-ion costs more up front, and Crown notes there is still uncertainty for some fleets about the long-term return. The case for lithium-ion rests on total cost: fewer spare batteries, no battery room, less maintenance labor, more uptime and a longer life. Hyster points out that around 80 percent of a forklift's total cost comes after the initial purchase.

A rough rule: the more shifts you run and the more you spend on battery changing and maintenance, the stronger the case for lithium-ion. A single-shift operation with existing chargers and good maintenance may find lead-acid cheaper over its life. Ask suppliers for a total cost of ownership comparison based on your own shift pattern, and check warranty terms carefully.

Which should you choose?

SituationUsually favors
Single shift, low hours, tight budgetLead-acid
Two or three shiftsLithium-ion
No space for a battery roomLithium-ion
Cold storage and freezersLithium-ion (with cold-rated options)
Older trucks with no approved lithium optionLead-acid

Frequently asked questions

How long does a lead-acid forklift battery last?
Manufacturers quote about 1,000 to 1,500 charge cycles when it is properly maintained, and Bobcat gives a typical life of 5 to 7 years. Life is shortened by deep discharging, heat, overcharging and poor watering.
Can I put a lithium battery in my existing forklift?
Sometimes, but only with a battery approved for that truck. The battery forms part of the truck's counterweight: Crown notes that lithium-ion batteries may need additional counterweight to maintain the truck's performance specifications, and the data plate lists the allowed battery weight range. Ask the truck manufacturer or dealer.
Do lithium forklift batteries need a charging room?
Manufacturers say lithium-ion batteries do not emit gas during charging, so they don't need the ventilated battery rooms that lead-acid batteries do. OSHA's battery charging rules still apply to the charging area, and you should follow the battery maker's instructions.
What is opportunity charging?
Topping up a battery during breaks and idle time instead of waiting until it is flat. Lithium-ion batteries are designed for it. Lead-acid batteries generally are not, unless the battery and charger are designed for opportunity charging.

Sources

We checked the facts in this guide against these sources. Standards and regulations change, so check the current version before relying on a specific requirement.

  1. Forklift batteries: a quick reference Crown Equipment
  2. Adopting lithium-ion forklifts in your cold storage environment Crown Equipment
  3. Lithium-ion battery FAQ Toyota Material Handling Europe
  4. Time to rethink your lift truck power (white paper) Hyster
  5. Forklift battery safety and maintenance tips Bobcat
  6. Happy batteries live longer (2015 handout) Raymond Corporation
  7. 29 CFR 1910.178(g), Changing and charging storage batteries OSHA

This guide is general information, not legal or safety advice for your site. See our disclaimer and editorial standards. Spotted something wrong? We correct errors quickly.