Forklift Guides

Pallet racking types explained

The main types of pallet racking, how each one stores and retrieves pallets, the trade-offs between access and density, and the load sign and inspection rules that apply.

Quick answerPallet racking ranges from selective racking, where every pallet can be reached directly, to high-density systems such as drive-in, push-back, pallet flow and mobile racking, which store more pallets in less space but give less direct access. Whatever the type, racks should display load plaques showing their rated capacity, be used within the design shown on the supplier's drawings and be inspected regularly, with damaged sections taken out of use.
Most common
Selective racking
US design standard
ANSI MH16.1-2023 (steel storage racks)
Cantilever standard
ANSI MH16.3
Key safety items
Load plaques, inspections, column protection

Racking decides how many pallets fit in a building, how quickly they can be reached and which trucks you need. Every design is a trade-off between selectivity (how easily you can reach any one pallet) and density (how many pallets fit in the space). This guide compares the main types and covers the safety rules that apply to all of them.

The main types at a glance

TypeAccessStock rotationDensity
SelectiveEvery pallet directlyAny orderLowest
Double-deepFront pallet directly, rear pallet behind itMostly LIFOHigher
Drive-inTruck drives into the rack, one end onlyLIFOHigh
Drive-throughTruck drives through, both ends openFIFO possibleHigh
Push-backFront pallet; others roll forward on cartsLIFOHigh
Pallet flowLoad one end, pick the other; gravity rollersFIFO (usually)High
MobileRows move to open one aisle at a timeAny orderVery high
CantileverArms with no front uprightsAny orderFor long items

LIFO means last in, first out. FIFO means first in, first out.

Selective racking

The familiar design: upright frames joined by horizontal beams, with pallets one deep on each side of an aisle. Every pallet can be reached without moving another. Wikipedia describes it as a common pallet racking system, giving easy access to all products at all times, and considerably cheaper per pallet position than high-density systems. The cost is floor space: each row of pallets needs an aisle wide enough for the trucks you use. Narrow-aisle trucks such as reach trucks reduce that space.

Double-deep racking

Selective racking two pallets deep. It removes some aisles, so it stores more in the same area, but the rear pallet can only be reached once the front one is moved. It normally needs reach trucks with extending forks that can reach the second pallet.

Drive-in and drive-through racking

Instead of beams at each level, pallets sit on rails along the sides of deep lanes, and the forklift drives into the lane to place or retrieve them. Drive-in racking is entered from one end, so it works on a LIFO basis. Drive-through is open at both ends, so it can be loaded from one side and picked from the other, which Wikipedia notes is advantageous for material with an expiration date. These systems suit large quantities of the same product. Operators drive inside the structure, so training for these conditions, and protecting the uprights, are important.

Note that ANSI MH16.1, the main US rack design standard, does not apply to drive-in or drive-through racks.

Push-back racking

Push-back racking organises storage by depth. Pallets sit on nested carts on slightly inclined rails. Placing a new pallet pushes the others back; removing the front pallet lets the next one roll forward. Wikipedia describes lanes up to six pallets deep. It is LIFO and greatly reduces aisle space, while the truck never has to enter the rack.

Pallet flow racking

Pallets travel along slightly inclined roller lanes from the loading side to the picking side, controlled by brakes. Loaded from the back and picked from the front, it gives FIFO rotation. It is used for high-throughput, date-sensitive stock. Pallet quality matters: damaged or non-standard pallets can jam some designs.

Mobile racking

Rows of racking sit on motorised bases running on floor rails, and move sideways to open an aisle wherever it is needed. Only one aisle is open at a time, so it suits slower-moving stock and cold stores, where space is expensive. Wikipedia notes it can halve the floor area needed, or double capacity in the same area.

Cantilever racking

Arms extend from a central column with no front uprights, so long and awkward items such as timber, pipe, steel and sheet materials can be loaded from the side. The RMI notes that long or bulky items may be stored in cantilever racks. Cantilever racks have their own US standard, ANSI MH16.3.

Load plaques and design drawings

The Rack Manufacturers Institute explains that load plaques serve as a constant reminder of the rated load capacity of the rack, and that the ANSI/RMI standard calls for rack installations to display them. Building inspectors may also require them. The ANSI summary of MH16.1 says all racking should have clearly posted load signage and be used within design limits.

The permitted configurations are shown on the Load Application and Rack Configuration (LARC) drawings supplied to the owner. The RMI warns that changing to a configuration that was not considered in the design, such as moving beam levels, may create an unsafe condition. Changes should be reviewed by a qualified engineer, and the plaques updated to match.

Never guess a rack's capacity. Beam capacity depends on the beam section, the span, the connectors and the vertical spacing between levels. If there is no load plaque, contact the rack supplier or a qualified engineer before loading it.

Inspections and damage

The ANSI summary of MH16.1 says column damage "is a leading cause of rack failure". The RMI recommends:

  • A program of regularly scheduled inspections by a qualified person, at least annually, with the results documented
  • Inspections after any impact, overload or event such as an earthquake
  • Isolating damaged sections immediately, unloading them and keeping them out of use until assessed
  • Having the manufacturer or a qualified engineer assess damage and approve repairs before the rack goes back into service

Look for bent or twisted uprights, damaged or deflected beams, missing beam locks or safety pins, damaged baseplates and missing anchors, bent bracing and frames that lean out of plumb.

Protecting racks from forklifts

Most rack damage comes from trucks. Column protectors (post protectors) fitted around the base of uprights, end-of-aisle guards, guide rails in narrow aisles and good lighting all reduce impacts. Operator training should cover load manipulation, stacking and unstacking and narrow aisles, which are all required workplace topics under OSHA's forklift standard (1910.178(l)(3)(ii)).

Frequently asked questions

What is the most common type of pallet racking?
Selective pallet racking, with beams and upright frames that give direct access to every pallet from an aisle. It is usually the cheapest per pallet position, but needs the most aisle space.
What is the difference between drive-in and drive-through racking?
Drive-in racking has entry from one side only, so the last pallet in is the first out (LIFO). Drive-through racking can be entered from both ends, so pallets can be loaded at one end and picked from the other (FIFO), which suits stock with expiry dates.
Do pallet racks need load signs?
The RMI says the ANSI/RMI standard calls for rack installations to display load plaques, which show the rated capacity. Building inspectors may also require them. Plaques must be updated if the rack configuration or loads change.
How often should pallet racking be inspected?
The RMI recommends a program of regularly scheduled inspections by a qualified person, at least annually, plus inspections after any damage or event such as an earthquake. Many sites also have staff report rack damage as soon as it happens.

Sources

We checked the facts in this guide against these sources. Standards and regulations change, so check the current version before relying on a specific requirement.

  1. Frequently asked questions Rack Manufacturers Institute (RMI)
  2. ANSI MH16.1-2023: Industrial steel storage racks ANSI
  3. Pallet racking Wikipedia

This guide is general information, not legal or safety advice for your site. See our disclaimer and editorial standards. Spotted something wrong? We correct errors quickly.